Field Setting Mode
NOTE
•
(*1)
The value is determined according to the type of outdoor unit.
•
(*3)
: Applies to the AE200DN**** model.
•
(*4)
: Applies to the AE160DN****/MIM-E03FN models.
DHW Heating : Code 30**
DHW Application (FSV#3011)
The FSV #3011 in the AI Home should be set to 1 or 2 to use DHW function.
If FSV #3011 is set to 1, the DHW operation starts based on the thermo on temperature. (In case of Heating/
Cooling - DHW Combined Operation Mode)
If FSV #3011 is set to 2, the DHW operation starts based on the thermo off temperature. (In case of Heating/
Cooling - DHW Combined Operation Mode)
DHW turns off if FSV #3011 is set to 1 and
DHW turns on if FSV #3011 is set to 2.)
Heat Pump Variables for Controlling DHW Tank (FSV#3021~3026)
• Maximum DHW tank temperature with the heat pump operation :
• Temperature difference determining the heat pump OFF temperature :
• Temperature difference determining the heat pump ON temperature :