Field setting mode
44
Field Setting Mode
Others : Code 50**/60**
Away mode (FSV#5011~5019)
• All the target temperatures – space heating and cooling, water law, DHW, Room temperature – are set to
the values defined in the above table under the Away mode.
NOTE
•
Economic DHW Heating (FSV#5021~5023)
• DHW heating only by the heat pump to save energy (Operated in Eco mode of AI Home)
Target DHW temperature is lower than the temperature set by user.
The temperature difference is defined by FSV #5021. (default: 5°C) If user sets the temperature 45°C,
the system sets the target temperature 40°C with the default setting.
– If user want additional energy saving, use a "Saving mode" (#5022, default : 0, OFF)
– The user can set the "Thermo On" temperature during "Saving mode" using FSV #5023
DB68-12922A-02_IB_24Y EHS AE7000D_EU_EN_.indd 44DB68-12922A-02_IB_24Y EHS AE7000D_EU_EN_.indd 44 2024-12-11 오전 10:04:432024-12-11 오전 10:04:43