Operating advanced function _33
• Code 30
✴✴
: User’s options for domestic hot water(DHW) tank heating
3011 : Application of DHW tank in user’s system
302
: Heat pump variables for tank temp. control and combination with booster heater
303
: Booster heater variables for combination with heat pump
304
: Periodical disinfection heating of water tank
305
: Off timer for power DHW mode by hot key of wired remote controller
3061 : Combination of external field solar panel for with heat pump for DHW heating
Field Setting Value
Main Menu &
Code
Sub Menu Function
Description
Sub
Code
Default
Min
Max
Step
Unit
DHW
Code 30
✴✴
Domestic Hot Water
Tank
Application
✴✴
11
0(No)
0
1(Yes)
-
-
Heat Pump
Max Temp
✴✴
21
50
45
55
1
˚C
Stop
✴✴
22
2
2
10
1
˚C
Start
✴✴
23
5
1
20
1
˚C
Min Operation
✴✴
24
5
0
20
1
min
Max Operation
✴✴
25
30
5
95
5
min
Interval
✴✴
26
3
0
10
0.5
hour
Booster Heater
Application
✴✴
31
1(On)
0(OFF)
1
-
-
Delay Time
✴✴
32
20
20
95
5
min
Overshoot
✴✴
33
0
0
4
1
˚C
Compensation Temp
✴✴
34
10
0
20
1
˚C
Disinfection
Application
✴✴
41
1(On)
0(OFF)
1
-
-
Interval
✴✴
42
Fri
Mon
Sun
1(All)
day
Start Time
✴✴
43
23
0
23
1
o'clock
Target Temp
✴✴
44
65
40
65
5
˚C
Duration
✴✴
45
10
5
60
5
min
Power DHW by User
Input
Timer OFF Function
✴✴
51
0(Off)
0
1(On)
-
-
Timer Duration
✴✴
52
60
30
300
10
min
Solar Panel
H/P Combination
✴✴
61
1(No)
0
1(Yes)
-
-