1-1
Chapter 1 Site Requirements
When planning the installation of your OfficeServ500 system, choose a site that meets the following
requirements.
y There is sufficient space for easy installation (Figure 1–1
) and adequate lighting.
y The location minimizes cable lengths. (See the Cable Requirements table in Chapter 3, “Specifica-
tions”, of the Samsung OfficeServ500 General Description guide.)
y The equipment should not be exposed to direct sunlight, corrosive fumes, dust, constant vibration or
strong magnetic fields such as those generated by motors and copy machines.
y A direct commercial AC power outlet is required. Do not use extension cords. Preferably, a dedicated
circuit should be used to minimize the risk of other electrical equipment being connected that could
adversely affect system operation.
y Ensure that all wires and cables going to and coming from the system are properly routed. Do not
cross fluorescent lights or run parallel with AC wires.
y The equipment must be located in an environment that will maintain a temperature range of 32°~77°F
(0°~25°C) and a humidity range of 10%~90% non-condensing.
y This equipment is to be installed only in Restricted Access Areas (e.g. dedicated equipment rooms,
equipment closets).
y Allow at least 25cm (10”) clearance on both sides and above the system to ensure proper ventilation
and access to the interior of the cabinet.
y Do not install in close proximity to a fire sprinkler head or to other sources of water.
y Space consideration must be made to allow floor or wall mounting. Do not wall mount a multiple cabi-
net system.
Meeting these requirements will help to ensure proper performance and greater life expectancy of the
system.