Alignment & Troubleshooting
Service Manual
4-125
Samsung Electronics
Low Heat Error is displayed on LCD
Wire connections
between FDB and
other devices are
all correct?
N.G
Make wire connections
to be completed
Check resistance
AC connector
below 10ohm
O.K
O.K
IN FDB PBA
Check 24V
(in 6pin connector No1)
Replace
FDB PBA
Go to Cover
Open Session
N.G
O.K
N.G
Replace
FUSER
In FDB PBA
Check
Lamp 1 sig(con. No. 2)
Relay On sig(con no.5)
Replace
MCB PBA