APPENDIX
Baud Rate Settings
Select the transfer speed of a selected communication protocol.
No. Baud Rate (BPS) SW2-#5 SW2-#6
1 2400 ON ON
2 4800 ON OFF
3 9600 (Default) OFF OFF
4 19200 OFF ON
Communication Method Settings
Select a communication method for the camera.
Function ON OFF
SW2-#7 Transfer Mode Switch RS-422(4Wire) RS-485(2Wire)
Communication Response Settings
Select a communication response method for the camera and controller: Response or No
Response.
Function ON OFF
SW2-#10 Response Mode Switch Response No Response
Termination Settings
To prevent the attenuation of communication signals between the camera and controller,
the items at the end of line must be set up with the termination settings.
Camera Input Position SW2-#8 SW2-#9
Termination of Longest Path ON ON
On the Path OFF OFF
M
The default value is shaded in each setting table.