59
Features & Operation
8. COMPULSORY OPERATION :
You can select the 5 Way function with
operating mode of the air conditioner for
more comfortable circumstances. You can
use the 5 Way function with the indoor unit
as well as the remote control. Thus, you can
use this function even though you have lost
your remote control.
Using with the indoor unit
Press the (ON/OFF)button one or more
times until the desired mode is selected.
To obtain a(n)... Then select...
Normal operating (STANDARD)mode
Reducing the
uncomfortable (NATURE)mode
temperature swing
Stronger air-conditioner
(QUENCHING)mode
environment faster
Energy saving (SAVING)mode
Quiet environment (SILENT)mode
To stop the operating, press the (ON/OFF)
button until all indicators turn off.
Note - Even if the air conditioner has been turned
on via the ON/OFF button, operations can still
be controlled using the remote control as usual.
9. SWING : BLADE-H is rotated vertically by
the stepping motor.
*Memory louver : When ON/OFF button is
pressed at stop state, the BLADE-H returns
to its original location which is operating
state before stop
*Swing Set : Press the button under the
remote control is displayed on LCD the
and the blades move up and down. If the one
more time press the button, blatles loca-
tion is stop.
10. 24-Hour ON/OFF Real Setting Timer. : The
air conditioner is turned ON at a specified
time using .
OFF TIMER : The air Conditioner is turned
OFF at a specified time using .
*ON TIMER : Only timer LED lights on.
*OFF TIMER : Both timer and operation
LED lights on.
11. SELF Diagnosis
12. BUZZER SOUND : Whenever the ON/OFF
button is pressed or whenever change
occurs to the condition which is set up or
select, the compulsory operation mode,
buzzer is sounded "beep"
Indoor unit room temperture sensor
error(open or short)
Check Point
LED DISPLAY
TIMER STD NATURE POWER SAVING SILENCE
LED
:
blinking
: LED off
Indoor unit heat exchanger tempertute
sensor error(open or short)
Indoor fan mal function
EEPROM error
Option error(option wasn’t set up or
option data error)