9. SWING : BLADE-H is rotated vertically by
the stepping motor.
*Memory louver : When ON/OFF button is
pressed at stop state, the BLADE-H returns
to its original location which is operating
state before stop
*Swing Set : Press the button under the
remote control is displayed on LCD the
and the blades move up and down. If the one
more time press the button, blade location
is stop.
10. 24-Hour ON/OFF Real Setting Timer. : The
air conditioner is turned ON at a specified
time using .
OFF TIMER : The air Conditioner is turned
OFF at a specified time using .
*ON TIMER : Only timer LED lights on.
*OFF TIMER : Both timer and operation
LED lights on.
11. SELF Diagnosis
12. BUZZER SOUND : Whenever the ON/OFF
button is pressed or whenever change
occurs to the condition which is set up or
select, the compulsory operation mode,
buzzer is sounded "beep"
83
Inverter Model
Indoor unit room temperature sensor
error(open or short)
Description
LAMP of Display Monitor
STD
TIMER
NATURE
POWER
SAVING SILENCE
: Lamp on
: Lamp flickering
: Lamp off
Indoor unit heat exchanger temper-
atute sensor error(open or short)
Indoor fan motor mal function
EEPROM error
option error
Abnormal communication
(Indoor - Outdoor unit)
Abnormal increase of operation
current
Abnormal increase of discharge and
OLP temperature
Over current of IPM circuit
Trouble of the PTC circuit of the out-
door
Trouble of AC current sensor
(open/short) and Leakage of refriger-
ant(R-22)
Outdoor unit temperature sensor error
(open or short)
- outdoor temp-sensor
- deice temp-sensor
- OLP temp-sensor
- discharge temp-sensor
- heatsink temp-sensor
XXXXX
X
XXXX
XXXX X
XXXX
XXXX
XX
XX
XX
XX
X
X
XX
X
X
X
X
XXX
XXX
Indoor unit
Normal operation and communica-
tion (Indoor - Outdoor unit)
Description
LAMP of inverter PBA
Yellow Blue Red
: Lamp on
: Lamp flickering
: Lamp off
Abnormal communication
(Indoor - Outdoor unit)
Trouble of the control power of the
outdoor
Abnormal increase of heatsink
temperature
Abnormal increase of discharge
temperature
Abnormal increase of operation current
Abnormal increase of OLP temperature
Over current of IPM circuit
Over voltage of IPM circuit
Trouble of option setting
Trouble of discharge temp-sensor
(open/short)
Trouble of outdoor temp-sensor
(open/short)
Trouble of deice temp-sensor
(open/short)
Trouble of heatsink temp-sensor
(open/short)
Trouble of DC link voltage circuit
Trouble of OLP temp - sensor
(open/short)
Trouble of AC current sensor
(open/short) and Leakage of refriger-
ant(R-22)
Over voltage and current of PFC circuit
X
XX
XX
XX
X
X
X
XX
X
X
X
X
X
X
Outdoor unit