Features & Operation
72
◆ Operating pattern Ts : Remocon setting temp.
◆ Operating specification
- Compressor on : Room temp. = Setting temp(Ts)+3ºC
- Compressor off : Room temp. = Setting temp(Ts)+5ºC
- The fan speed of indoor unit follows the setting volume of remote control
Heating Operation
3
Turbo Operation
4
◆ Operating pattern
◆ Operating specification
The turbo function operates for 30 minutes with the maximum setting before returning auto-
matically to the mode and temperature previously selected.
00150A(2)-54~98 2/5/01 11:52 AM Page 72