Sleeping Operation
5
Cooling operation
◆ Operating pattern
Ts : Remocon setting temp.
◆ Operating specification
When you set the sleep mode, the following movement will start to avoid over cooling.
• The indoor fan speed is fixed by setting the remote controller.
• The setting temperature will rise by 1ºC at the starting operation and by 1ºC one hour later.
• The operation will stop after 6 hours.
Heating operation
◆ Operating pattern Ts : Remocon setting temp.
◆ Operating specification
When you set the sleep mode, the following movement will start to avoid overheating.
• The indoor fan speed is fixes by setting the remote controller.
•The setting temperature will be dropped by 1ºC one hour later.
•The operation will stop after 6 hours.