● 18K/ 24K
◆ If indoor heat exchanger temp. is over 52°C, outdoor fan is low.
◆ If indoor heat exchanger temp. is over 56°C, outdoor fan turns off.
◆ If indoor heat exchanger temp. is over 60°C, outdoor compressor stops and Indoor
fan speed is low.
◆ After compressor and fan are off if indoor heat exchanger temp.
is below 50°C, indoor fan and outdoor compressor and outdoor fan operate normally.