EasyManua.ls Logo

Sanyo PDG-DHT100L - Page 44

Sanyo PDG-DHT100L
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-44-
Electrical Adjustment
n Wind Sensor calibration
1. Enter the service mode, select group no. 240 and
item no. “0” .
2. To start the adjustment, change data value from 0
to 1. After the auto-calibration completed, "OK" will
appear on the screen.
IMPORTANT
Before taking this adjustment, you need to replace the air
filter with new one or scroll up the filter sheet and make
sure the cabinet top, filter cover and filter cartridge are
securely installed.

Table of Contents

Other manuals for Sanyo PDG-DHT100L

Related product manuals