WARNING : USE UV RADIATION EYE AND
SKIN PROTECTION DURING
SERVICING
CAUTION: To prevent suffer of UV radiation,
those adjustments must be
completed within 25 minutes.
Optical components adjustments procedure
Adjustment optical components location
When adjusting optical component, adjust each
adjustment item in numerical order.
Incorrect adjustment steps may produce improper
adjustment. The items adjusted correctly can be
omitted from the steps.
(1) Back focus of LCD panel adjustment.
(2) Integrator-lens-in 1 adjustment. (turn)
(3) Integrator-lens-in 2 adjustment. (up / down)
(4) Integrator-lens-out adjustment. (left / right)
(5) Condenser-lens adjustment.
(6) Relay-lens adjustment.
(7) Convergence adjustment.
(8) Prism PBS adjustment.
(9) Polarized glass adjustment. (Contrast adjustment)
(10) Optical filter adjustment. (Contrast adjustment)
Contrast
adjustment
(9), (10)
(2), (3)
Integrator lens in
adjustment
(5)
Condenser lens
adjustment
(8)
Prism PBS
adjustment
(4)
Integrator lens out
adjustment
(1)
Back focus
of LCD panel
adjustment
(7)
Convergence
adjustment
(6)
Relay lens
adjustment
R
G
B
Optical adjustment
- 72 -