- 42 -
Service Adjustment
[Adjustment Condition]
Input signal
Video signal .................................
1.0Vp-p/75W terminated, 16 steps gray scale
(Composite video signal)
Component Video signal ........... 0.7Vp-p/75W terminated, Color Bar
(Component video signal)
Computer signal ........................... 0.7Vp-p/75W terminated, 16 steps gray scale
pattern
Image control mode ............... “STANDARD” mode unless otherwise noted.
Note:
* Please refer to “Service Adjustment Menu Operation for entering the service mode
and adjusting the service data.
White 100%
Black 100%
Circuit Adjustments
CAUTION: The each circuit has been made by the fine adjustment at factory. Do not attempt to adjust the following adjust-
ments except requiring the readjustments in servicing otherwise it may cause loss of performance and product
safety.
16 steps gray scale pattern
WARNING : USE UV RADIATION EYE AND SKIN PRO-
TECTION DURING SERVICING.
CAUTION:
To prevent suffer of UV radiation, those adjustments must be
completed within 25 minutes.