- 57 -
Service Adjustment
Group/
Item
Item Name Function Initial Range Note
Group 250 FAN Cntorol
0 FAN1 MIN ADJUST (DAC)
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
45 0 - 255
1 FAN1 MAX ADJUST (DAC) 235 0 - 255
2 FAN2 MIN ADJUST (DAC) 45 0 - 255
3 FAN2 MAX ADJUST (DAC) 235 0 - 255
4 FAN3 MIN ADJUST (DAC) 45 0 - 255
5 FAN3 MAX ADJUST (DAC) 235 0 - 255
6 Not used
7 Not used
Group 251
Not used
Group 252 Fan Option
0 HI-LAND SWITCH
0: Normal, 1: Hi-Land, 2-4: Hi-Land
1-3
0 0 - 5
1 SAFETY SWITCH For test purpose 0 0 - 6
2 FAN MANUAL SWITCH 0: Auto, 1: Manual 0 0 - 3
3 FAN1 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Maual
switch is 1
100 0 - 255
4 FAN2 MANUAL VOLTAGE 100 0 - 255
5 FAN3 MANUAL VOLTAGE 100 0 - 255
6 Not used
7 Stand Mode
Stand mode setting
0: Normal(Free) 1: Normal(Fixed)
2: Celling 3: Down 4: Up
0 0 - 4
8
Fan Offset Voltage Update In-
terval
filter clogged Fan Voltage Update
interval time ( sec.)
60 1 - 600
Group 253 Fan Tem Error Setting (Memorized) Normal Ceiling Down Up
0
Not used
1
Not used
2
Not used
3
Not used
4
Not used
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
41
32
41
32
41
32
41
32
30-100
Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
51
57
51
57
51
57
51
57
30-100
Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
73
78
73
78
73
78
73
78
30-100
Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
100
100
100
100
0-100
Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
9 Temp C-A Warning (Normal)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
100
100
100
100
0-100
Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
42
32
42
32
42
32
42
32
30-100
Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco (Panel)
52
58
52
58
52
58
52
58
30-100
Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco (Lamp)
75
80
75
80
75
80
75
80
30-100
Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Eco (Clogging Det.)
100
100
100
100
100
100
100
100
0-100
Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Eco (Clogging Det.)
100
100
100
100
100
100
100
100
0-100
Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
15 Temp A Warning Oset (Temp)
Oset of Temp Error (Temp.)
Error Setting Value is increased X°C at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
16 Temp B Warning Oset (Temp) 5
17 Temp C Warning Oset (Temp) 5
18 Temp B-A Warning Oset (Temp) 0
19 Temp C-A Warning Oset (Temp) 0
20 Temp A Warning Oset (Time)
Oset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
1
21 Temp B Warning Oset (Time) 1
22 Temp C Warning Oset (Time) 1
23 Temp B-A Warning Oset (Time) 1
24 Temp C-A Warning Oset (Time) 1
25
Factory Mode For factor use
0
Down
Up
Celling
Normal