1 Remove 4 hex screws A and take the LCD/Prism ass’y off upward.
2 Remove 3 screws B and take the Glass Holder, and then pull the polarized
Glass-Out upwards off. These glasses are mounted for R, G and B LCD
panels respectively.
Note:
To avoid the CG and focus alignments slipping off, please be careful to han-
dle the LCD/Prism ass'y.
Polarized Glass-Out removal
B
B
B
Polarized Glass-Out
* The polarized glass-out for green panel have
2 green marking on top of the glass, and
should be placed as in Fig.4-2.
Pre-polarized Glass-Out
* The pre-polarized glass-out should be placed
for green and blue panels, not for red panel.
* The pre-polarized glass-out have 1 marking
on top of the glass, and should be placed as
in Fig.4-2.
Marking (*)
Fig.4-2
Polarized Glass-
Out (*)
Pre-Polarized
Glass-Out (*)
* Glasses should be placed as the
sheet attached side comes to the
LCD panel side.
Optical Pats Disassemblies