-73-
Electrical Adjustment
Group/
Item
Item Name Function Initial Range Note
Group 253 Fan Tem Error Setting (Memorized) Normal Ceiling L1 L2
0 Temp A Warning (High)
Temp. A to judge the Temp Error at High
(Room)
43 43 43 43 30-100
L1
160°
200°
20°
340°
(-20°)
(-160°)
L2
Normal Ceiling
Off L1 L2
Off Normal Up Down
On Ceiling Up Down
Slant
Ceiling
Definition of Slant
Off -20° ~ 20°
L1 20° ~ 160°
L2 -20° ~ -160°
1 Temp B Warning (High)
Temp. A to judge the Temp Error at High
(Lamp)
60 60 60 60 30-100
2 Temp C Warning (High)
Temp. A to judge the Temp Error at High
(Panel)
48 48 48 48 30-100
3 Temp B-A Warning (High)
Temp. B-A to judge the Temp Error at High
(Clogging Det.)
100 100 100 100 0-100
4 Temp C-A Warning (High)
Temp. C-A to judge the Temp Error at High
(Clogging Det.)
100 100 100 100 0-100
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at Normal
(Room)
43 43 43 43 30-100
6 Temp B Warning (Normal)
Temp. A to judge the Temp Error at Normal
(Lamp)
61 61 61 61 30-100
7 Temp C Warning (Normal)
Temp. A to judge the Temp Error at Normal
(Panel)
48 48 48 48 30-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100
9 Temp C-A Warning (Normal)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100
10 Temp A Warning (Eco) Temp. A to judge the Temp Error at Eco (Room) 43 43 43 43 30-100
11 Temp B Warning (Eco) Temp. A to judge the Temp Error at Eco (Lamp) 62 62 62 62 30-100
12 Temp C Warning (Eco) Temp. A to judge the Temp Error at Eco (Panel) 48 48 48 48 30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100
15 Temp A Warning Offset (Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at the
below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
10 0-100
16 Temp B Warning Offset (Temp) 11 0-100
17 Temp C Warning Offset (Temp) 13 0-100
18 Temp B-A Warning Offset (Temp) 11 0-100
19 Temp C-A Warning Offset (Temp) 13 0-100
20 Temp A Warning Offset (Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X minute at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
30 0-40
21 Temp B Warning Offset (Time) 15 0-40
22 Temp C Warning Offset (Time) 15 0-40
23 Temp B-A Warning Offset (Time) 15 0-40
24 Temp C-A Warning Offset (Time) 15 0-40
Group 254 Fan Control Range Setting (Temp./REV) Normal Ceiling L1 L2
0 High Fan Control Min Temp
Temp Senser Control Start/End Tem.p at High
26 26 26 26 20-100
L1
160°
200°
20°
340°
(-20°)
(-160°)
L2
Normal Ceiling
Off L1 L2
Off Normal Up Down
On Ceiling Up Down
Slant
Ceiling
Definition of Slant
Off -20° ~ 20°
L1 20° ~ 160°
L2 -20° ~ -160°
1 High Fan Control Max Temp 35 35 35 35 20-100
2 High Fan1 Min
Fan Operation REV(Min/Max) setting at High
(rpm)
2775 2775 2775 2775 0000-9990
3 High Fan1 Max 2975 2975 2975 2975 0000-9990
4 High Fan2 Min 1800 1800 1800 1800 0000-9990
5 High Fan2 Max 2555 2555 2555 2555 0000-9990
6 High Fan3 Min 4700 4700 5900 5900 0000-9990
7 High Fan3 Max 4800 4800 6100 6100 0000-9990
8 High Fan4 Min 3120 3120 3120 3120 0000-9990
9 High Fan4 Max 5865 5865 5865 5865 0000-9990
10 Normal Fan Control Min Temp
Temp Senser Control Start/End Tem.p at
Normal
26 26 26 26 20-100
11 Normal Fan Control Max Temp 35 35 35 35 20-100
12 Normal Fan1 Min
Fan Operation REV(Min/Max) setting at
Normal (rpm)
2495 2495 2495 2495 0000-9990
13 Normal Fan1 Max 2795 2795 2795 2795 0000-9990
14 Normal Fan2 Min 1625 1625 1625 1625 0000-9990
15 Normal Fan2 Max 2245 2245 2245 2245 0000-9990
16 Normal Fan3 Min 3650 3650 4850 4850 0000-9990
17 Normal Fan3 Max 3725 3725 5000 5000 0000-9990
18 Normal Fan4 Min 2605 2605 2605 2605 0000-9990
19 Normal Fan4 Max 5275 5275 5275 5275 0000-9990
20 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.p at Eco
26 26 26 26 20-100
21 Eco Fan Control Max Temp 35 35 35 35 20-100
22 Eco Fan1 Min
Fan Operation REV(Min/Max) setting at Eco
(rpm)
2210 2210 2210 2210 0000-9990
23 Eco Fan1 Max 2610 2610 2610 2610 0000-9990
24 Eco Fan2 Min 1450 1450 1450 1450 0000-9990
25 Eco Fan2 Max 1935 1935 1935 1935 0000-9990
26 Eco Fan3 Min 2600 2600 3800 3800 0000-9990
27 Eco Fan3 Max 2650 2650 3900 3900 0000-9990
28 Eco Fan4 Min 2090 2090 2090 2090 0000-9990
29 Eco Fan4 Max 4685 4685 4685 4685 0000-9990

Table of Contents

Other manuals for Sanyo PLC-XT35L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-XT35L and is the answer not in the manual?

Sanyo PLC-XT35L Specifications

General IconGeneral
BrandSanyo
ModelPLC-XT35L
CategoryProjector
LanguageEnglish

Related product manuals