-71-
Electrical Adjustment
GROUP NO. ITEM FUNCTION RANGE INITIAL VALUE NOTE
0 TERM_1
(1) 75 ohm terminate On / Off (0: Off, 1: On)
(2)
Analog filter On/Off (0: Off, 1: On) on Input board side
0 / 1 0
1 TEMR_2 Analog filter On/Off (0: Off, 1: On) on Main Board side 0 / 1 0
140 Fan Output Level
0 Fan A Min Fan A Driving Voltage Adj. at TP7611 0 ~ 255 150 * Fan Driving Voltage Adj.
1 Fan A Max Fan A Driving Voltage Adj. at TP7611 0 ~ 255 48 * Fan Driving Voltage Adj.
2 Fan B Min Fan B Driving Voltage Adj. at TP2661 0 ~ 255 208 * Fan Driving Voltage Adj.
3 Fan B Max Fan B Driving Voltage Adj. at TP2661 0 ~ 255 14 * Fan Driving Voltage Adj.
4 Fan C Min Fan C Driving Voltage Adj. at TP2671 0 ~ 255 192 * Fan Driving Voltage Adj.
5 Fan C Max Fan C Driving Voltage Adj. at TP2671 0 ~ 255 28 * Fan Driving Voltage Adj.
6 Fan D1 Min Fan D1 Driving Voltage Adj. at TPFN1 0 ~ 255 192 * Fan Driving Voltage Adj.
7 Fan D1 Max Fan D1 Driving Voltage Adj. at TPFN1 0 ~ 255 32 * Fan Driving Voltage Adj.
8 Fan D2 Min Fan D2 Driving Voltage Adj. at TPFN2 0 ~ 255 192 * Fan Driving Voltage Adj.
9 Fan D2 Max Fan D2 Driving Voltage Adj. at TPFN2 0 ~ 255 32 * Fan Driving Voltage Adj.
10 Fan D3 Min 0 ~ 255 –
11 Fan D3 Max 0 ~ 255 –
12 Fan D4 Min 0 ~ 255 –
13 Fan D4 Max 0 ~ 255 –
141 Fan Option
0 Fan Output Level 0 : Max / 1: Factory / 2 : Auto / 3 : Min / 99: Menu 0 ~ 3, 99 99
1 Fan Cooling Mode 0: Default, 1: FAN_C _MAX Fixed 0 ~ 1 0
150 Factory Set (Reset)
0 Factory Set Execute Factory setting when the value reaches 10. 0 ~ 10 0
1 Destination 0: English, 1: Japanese 0 ~ 1 1
170 Flow Sensor
0 Flow Sensor Calibration
Flow Sensor Offset Calibration
Execute auto-calibration when the value is set to 1
0 ~ 1 0 * Filter Calibration Adj.
1 Flow Sensor Offset Minimum Flow Sensor Minimum Offset Value 0 ~ 1023 0
2 Flow Sensor Offset Maximum Flow Sensor Maximum Offset Value 0 ~ 1023 0
3 Flow Sensor Calibration Error Log
Auto-calibration Error Log
0: No Error
10: Unstabled at Minimum
11: Out of Range at Minimum
20: Unstabled at Maximum
21: Out of Range at Maximum
4 Clog Check Enable
Cloggle Detection with Flow Sensor
0: Disable, 1: Enable
0 ~ 1 1
171 Flow Sensor
0 Ideal Flow Data Read only
1 Flow Difference Data Read only
2 Clog Detect Flow Difference Data Read only
3 Warn Detect Flow Difference Data Read only
4 Press Add Data Read only
5 Filter Scroll Timer (Filter used time) Read only
175 Filter
0 Take up Bend Remove the filter bending 0 ~ 1 0
1 Take up Bend Remove the filter bending 0 ~ 1 0
2 Take up Times Filter Scroll Remeining Times (Read only) 9
3 Take up Time Reset
Reset the Filter Scroll Times
Reset when the value reaches 10
0 ~ 10 0
4 Scroll Counter Reset Time Reset Times of Sccroll Counter 0 ~ 255 0
176 Filter Display
0 Filter Icon display 0 : disable / 1 : Enable 0 / 1 1
177 Filter Timer Reset
0 Filter Counter Reset Times User Menu Filter Counter Reset Times 0 ~ 255 0
180 DDC Setting
0 HDCP EDID Data Setting 0 : EDID Data for DVI / 1 : EDID Data for HDCP 0 / 1 1
1 DDC Data Automatic Renewal 0 : Enable / 1 : Disable 0 / 1 0
190 Panel Life Test Pattern Display
0 Panel Life Test Pattern 0 : White 73% Raster Step Pattern Display / 1 : Normal 0 / 1 1
200 Panel Option
0 Gamma Instance
Gamma IC direct
(Gamma IC directed here is displayed by the following
service mode)
(900 / 910 / 920 / 940 / 950 / 951 / 952 / 960 / 970 /
98000 : 74h / 1 : 76h
0 ~ 1 0
280 Panel Option
0 G SIG Center 0 ~ 63 32
1 B SIG Center 0 ~ 63 32