EasyManua.ls Logo

Sanyo PLV-Z3 - 8. OPTICAL UNIT AND FAN REMOVAL

Sanyo PLV-Z3
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mechanical Disassemblies
-12-
7. LAMP BALLAST UNIT REMOVAL
1. Remove 4 screws A to take the Filter Holder off.
2. Remove 3 screws B to take the Filter Board off.
3. Remove 3 screws C to take the Inlet Board off.
Filter Board
Fig. 7-1
A
A
A
A
B
B
B
C
Filter Holder
8. OPTICAL UNIT AND FAN REMOVAL
1. Remove a screw A to take the Thermostat Switch
upward off.
2. Remove a screw B to take the Lamp Socket off.
3. Remove 3 screws C to take the Fan Cover off.
4. Remove 8 screws D to take the Optical Unit off.
5. Remove 2 screws E and 2 screws F to take the Fan
(FAN903) off.
Fig. 8-1
Thermostat
Switch
A
B
C
C
D
D
Lamp Socket
FN903
Inlet Board
Fig. 7-2
Fan
Cover
C
E
Rib
Fig. 8-2
D
D
D
D
D
D
E
F
F
Slit
Mounting
Exhaust Fan

Other manuals for Sanyo PLV-Z3

Related product manuals