16
AVOID:
heat sources, exhaust fans, etc. (Fig. 3)
damp, humid or uneven locations.
DO:
choose a place as cool as possible.
choose a place that is well ventilated.
allow enough room around the unit for air
intake/exhaust and possible maintenance.
(Figs. 4a and 4b)
provide a solid base (concrete block, 10
40 cm
beams or equal), a minimum of 10 cm above ground
level to reduce humidity and protect the unit against
possible water damage and decreased service life.
(Fig.5)
use lug bolts or equal to bolt down unit, reducing
vibration and noise.
Outdoor Unit
Outdoor unit
Hot air
Heat source
Exhaust fan
Fig. 3
Fig. 3
Min.
1 cm
Min.
1 cm
Min.50 cm
Min.10 cm
Air in
Air in
Air
discharge
Anchor bolts
(4 pieces)
Min. 10 cm
Min.
2 m
Min.
2 m
Obstacle above
Ground
Obstacle
Air
dis-
charge
Side View
Fig. 4b
Required space around the unit.
Top View
Fig. 4a
Fig. 5