2-3. Other Component Specifications
11
<Only for SAP-C121 models>
Thermostat (Fan Speed Control 23S) MQT5S
Switching temp. °C
high ➞ LOW 28.5°C ± 1.5
low ➞ HIGH 31.5°C ± 2
Contact rating AC 220V, 3A
<Only for SAP-C121 models>
PTC Thermistor (TH) TDK 101YV
Resistance Ω (at 25°C) 100 ± 20%
4-way Valve (20S) LB81012 (Coil), VK1100B (Valve)
Coil rating AC 220/240V, 50/60Hz, 6W
Coil resistance Ω (at 20°C) 3,030 ± 7%
Thermostat (Defrost thermo. 23D) TRS02-12MSR
Operating temp. °C ON 12 ± 2
Diff. 8 deg. below
Power Relay (PR) DFU24D1-F (M)
Coil rating DC 24V
Coil resistance Ω (at 20°C) 650 ± 10%
Contact rating AC 250V, 20A
Outdoor Unit SAP–C71GHA
SAP–C91GHA
SAP–C121GHA
Thermistor (Room sensor) DTN-TKS128B
Resistance kΩ 25°C 5.0 ± 3%
Thermistor (Coil sensor) DTN-TKS131B
Resistance kΩ 0°C 15.0 ± 2%
Transformer (TR) ATR-J105
Rating Primary AC 230V, 50/60Hz
Secondary 19V, 0.526A
Capacity 10VA
Coil resistance Ω (at 21°C) Primary (WHT – WHT): 205 ± 10%
Secondary (BRN – BRN): 2.0 ± 10%
Thermal cut-off temp. 150°C
Indoor Unit SAP–K71GJHA
SAP–K91GJHA
SAP–K121GJHA