Operation with the Remote Control Unit (continued)
NOTE
This appliance has a built-in 3-minute time delay circuit to ensure
reliable operation. When the operation button is pressed, the
compressor will start running within three minutes. In the event of
power failure, the unit will stop. When the power is restored, the
unit will restart automatically after three minutes.
3. Adjusting the
Fan Speed
A. Automatic Simply set the FAN SPEED selector button to the position.
A microcomputer in the air conditioner automatically controls the fan
speed when the
mode is selected. When the air conditioner starts
operating, the difference between the room temperature and the set
temperature is detected by the microcomputer which then automatically
switches the fan speed to the most suitable level.
Cooling and DRY mode:
When difference between
room temperature and set
temperature is
FAN SPEED
2°C and over High
Between 2°C and 1°C Medium
Below 1°C Low
Heating mode:
When difference between
room temperature and set
temperature is
FAN SPEED
2°C and over High
Below 2°C Medium
B. Manual If you want to adjust fan speed manually during operation, just set the
FAN SPEED selector button as desired. [
, ,or ]
14 OI-396-14EG