Power Source 220–240V Single phase 50Hz
Voltage rating 220/230/240 V
Performance Cooling Heating
Capacity kW 3.20 / 3.20 / 3.25 3.70 / 3.75 / 3.80
BTU/h 10,900 / 10,900 / 11,100 12,600 / 12,800 / 13,000
Air circulation (High)
Moisture removal (High) Liters/h 1.45 —
Electrical Rating Cooling Heating
Available voltage range V 198 ~ 264
Running amperes A 5.8 / 5.8 / 5.9 5.9 / 5.9 / 6.0
Power input W 1,220 / 1,240 / 1,280 1,230 / 1,260 / 1,290
Power factor % 96 / 93 / 90 95 / 93 / 90
C.O.P. W/W 2.62 / 2.58 / 2.54 3.01 / 2.98 / 2.95
Compressor locked rotor amperes A 32 / 33 / 35 32 / 33 / 35
Features
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit Wireless remote control unit
Timer 1-hour OFF / 12-hours ON or OFF
Fan speeds Indoor / Outdoor 3 and Auto / Auto (Hi,Lo)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable, Anti-Mold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R22 / 1,010
Refrigerant control Capillary tube
Operation sound Indoor : Hi / Me / Lo dB-A 40 / 38 / 36 39 / 38 / 36
Outdoor : Hi dB-A 45 46
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 7.5
Refrigerant Narrow tube mm (in.) 6.35(1/4)
tube diameter Wide tube mm (in.) 12.7(1/2)
Refrigerant tube kit / Accessories Optional / Hanging wall bracket
Dimensions & Weight
Remarks:
Rating conditions are:
Cooling : Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating : Indoor air temperature 20°C D.B.