5
Controller PCB POW–C186CMH
Control circuit fuse 250 V– 3 A
Type Rotary (Hermetic)
Compressor model ... Number C–R95H5K ... 2 / 80696745–S ... 2
Nominal output W 950 x 2
Compressor oil ... Amount cc SUNISO 4GSD–T ... 650 x 2
Coil resistance (Ambient temp. 25°C) Ω C – R : 2.88
C – S : 6.87
Type External (OLR 1, 3) External (OLR 2, 4)
Overload relay ... Number MRA99089–9201 ... 2 CS–7C115 ... 2
Safety
Operating
Open °C 145 ± 5 115 ± 3
devices
temp.
Close °C 69 ± 11 95 ± 5
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 16.5 A —
Run capacitor µF 22.5 ... 2
... Number VAC 400 ... 2
Type Propeller
Number ... Dia. mm 1 ... ø400
Fan motor model ... Number SG6–51B5P ... 1
No. of poles ... rpm (230 V,High) 6 ... 910
Nominal output W 50
Coil resistance (Ambient temp. 20°C) Ω WHT – BRN : 92.1
WHT – PNK: 196.4
Safety Type Internal protector
devices
Operating
Open °C 130 ± 8
temp.
Close Automatic reclosing
Run capacitor
µF 2.0
VAC 480
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.6
Face area m
2
0.453
External Finish Acrylic baked-on enamel finish
Heat
Exch. Coil
CompressorFan & Fan Motor
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
outdoor Unit SAP–MC1827GH5