Sanyo SAP-KM97GHS5A - Recommended Wire Length and Diameter

Sanyo SAP-KM97GHS5A
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Be sure to comply with
local codes on running the
wire from the indoor unit to
the outdoor unit (size of
wire and wiring method,
etc.).
Each wire must be firmly
connected.
No wire should be allowed
to touch refrigerant tubing,
the compressor, or any
moving part.
To avoid the risk of electric
shock, each air conditioner
unit must be grounded.
Be sure to connect the
power supply line to the
outdoor unit as shown in
the wiring diagram. The
indoor unit draws its power
from the outdoor unit.
Regulations on wiring diameter differ from locality to locality.
For field wiring requirements, please refer
to your local electrical codes. Carefully observe these regula-
tions when carrying out the installation.
Table 2 lists recommended wire lengths and size for power
supply systems.
Refer to the WIRING SYSTEM DIAGRAM for the meaning of
"A", "B" and "C" in Table 2.
NOTE
20
WARNING
9-3. Recommended Wire Length and Diameter
WARNING
# ······ AWG (American Wire Gauge)
Table 2
(A) Power Supply Wiring Length (m) (B) Power Line Length (m) (C) Cont rol Line
2
(#14)
3.5
(#12)
2
(#14)
MC1827 18 27 20 20
1
2
4
5
6
7
3
1
2
4
5
6
8
8
7
3
Outdoor unit
Terminal 8PA
Indoor
unit A
Terminal
220 V
Grounding line
Power
line
Low voltage
control line
1
2
4
5
6
7
3
1
2
4
5
6
7
3
Terminal 8PB
Grounding line
Power
line
Low voltage
control line
Indoor
unit B
Terminal
2
3
1
Power supply
Single-Phase,
50Hz, 220V
Grounding
line
Terminal
3P
220 V
220 V
220 V
B
B
C
C
A
WIRING SYSTEM DIAGRAM
CAUTION
20A
Fuse or Circuit
Capacity
0.75
(#18)
Cross Sectional
Area (mm
2
)
Model