30
11-2-2.Neither indoor nor outdoor unit runs.
A. Power is not supplied.
B. Check "OPERATION selector" switch in the indoor unit.
C. Check remote control unit.
NO
Check power supply.
Power is being supplied to the
outdoor unit.
Circuit breaker
is tripped.
Power failure
Reset breaker.
Wait for recovery
or contact power
company.
YES
NO
OPERATION selector switch is set
in ON position.
Set OPERATION selector switch
to ON.
Switch Ass'y or indoor PCB Ass'y
is defective.
OK
Try to run with another remote
control unit.
First remote control unit is defective.
Check for residue buildup on
transmitter of remote control unit.
Check for residue buildup on remote
control receiver on front of indoor
unit.
Clean transmitter.
Clean receiver.

Table of Contents