-52-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
19 DIMMER_LEVEL_AUTO Current Y Level (Read only) - -
20 DIMMER_LEVEL_NORMAL Dim Level at Normal 0 - 15 15
21 DIMMER_LEVEL_ECO Dim Level at Eco 0 - 15 0
23 VOLTAGE_LEVEL Lamp Voltage (Read only) - -
220 Projector Error Log
0 Warning_Log_1 Latest Error log 0 - 32767 0
: : : : :
49 Warning_Log_50 50th Error log 0 - 32767 0
50 Warning_Log Reset Log is cleared when the value is set to 10. 0 ~ 10 0
235 Shutter
0 PRE_MOTION Shutter Warm - up Operation (0: Yes, 1: No) 0 - 1 Initial: 1 / Shipping: 0
1 CMP_TRM Chattering Detecting Term 0 - 32767 7000
2 OUT_DLY_TRM Output Term 0 - 32767 15000
3 CMP_CHK_CNT Count of Information Sync 0 - 15 10
4 OPEN_DLY Open Output Delay 0 - 63 0
5 CLOSE_DLY Close Output Delay 0 - 63 0
6 Position Check Time Position Check Time 1 - 255 50
8 Enable Close Cmd Shutter Close Command 0: Disable, 1: Enable 0 - 1 1
9 Speed Control Shutter Speed 0 - 255 0
240 Flow Calibration
0 Flow Calibration Exe
Flow Sensor Offset Calibration Start calibration when the value
is set to 1.
0 - 1 0
* Wind sensor calibra
-
tion.
1 Flow Calibration Error Log
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
- 255
2 Clog Check Enable Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable) 0 - 1 Initial: 0 / Shipping: 1
3 Air Inlet Check Enable Air inlet Error Detection by Wind Sensor (0: Disable, 1: Enable) 0 - 1 Initial: 0 / Shipping: 1
4 Time Limit Auto Scroll Enble Auto Scroll (0: Disable, 1: Enable) 0 - 1 1
5 Clog Auto Cooling Enable Auto Cooling at Clog (0: Disable, 1: Enable) 0 - 1 1
6 Scroll Fail Auto Cooling Enable Auto Cooling at Scroll Error (0: Disable, 1: Enable) 0 - 1 1
241 Flow Ideal Data (Value will be set after calibration)
0 Flow Ideal Data 1 Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1 0 - 1023 263
1 Flow Ideal Data 2 Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2 0 - 1023 263
2 Flow Ideal Data 3 Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3 0 - 1023 308
3 Flow Ideal Data 4 Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4 0 - 1023 328
4 Flow Ideal Data 5 Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5 0 - 1023 346
5 Flow Ideal Data 6 Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6 0 - 1023 361
6 Flow Ideal Data 7 Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7 0 - 1023 371
7 Flow Ideal Data 8 Flow Sensor Theory Value No.8 Corresponding to Fan Volt No.8 0 - 1023 383
242 Flow Calib. Fan Volt (Not Memorized)
0 Flow Calib Fan Volt 1 Flow Sensor Calibration Fan Voltage No.1 [x10 V] 0 - 255 42
1 Flow Calib Fan Volt 2 Flow Sensor Calibration Fan Voltage No.2 [x10 V] 0 - 255 50
2 Flow Calib Fan Volt 3 Flow Sensor Calibration Fan Voltage No.3 [x10 V] 0 - 255 60
3 Flow Calib Fan Volt 4 Flow Sensor Calibration Fan Voltage No.4 [x10 V] 0 - 255 75
4 Flow Calib Fan Volt 5 Flow Sensor Calibration Fan Voltage No.5 [x10 V] 0 - 255 90
5 Flow Calib Fan Volt 6 Flow Sensor Calibration Fan Voltage No.6 [x10 V] 0 - 255 105
6 Flow Calib Fan Volt 7 Flow Sensor Calibration Fan Voltage No.7 [x10 V] 0 - 255 120
7 Flow Calib Fan Volt 8 Flow Sensor Calibration Fan Voltage No.8 [x10 V] 0 - 255 138
243 Flow Calib Effective Difference (Not Memorized)
0 Flow Calib Effective Diff 1 Flow Sensor Calibration Range Diff No.1 [ADC] 0 - 1023 300
1 Flow Calib Effective Diff 2 Flow Sensor Calibration Range Diff No.2 [ADC] 0 - 1023 300
2 Flow Calib Effective Diff 3 Flow Sensor Calibration Range Diff No.3 [ADC] 0 - 1023 300
3 Flow Calib Effective Diff 4 Flow Sensor Calibration Range Diff No.4 [ADC] 0 - 1023 300
4 Flow Calib Effective Diff 5 Flow Sensor Calibration Range Diff No.5 [ADC] 0 - 1023 300
5 Flow Calib Effective Diff 6 Flow Sensor Calibration Range Diff No.6 [ADC] 0 - 1023 300
6 Flow Calib Effective Diff 7 Flow Sensor Calibration Range Diff No.7 [ADC] 0 - 1023 300
7 Flow Calib Effective Diff 8 Flow Sensor Calibration Range Diff No.8 [ADC] 0 - 1023 300
244 Flow Clog Threshold (Not Memorized )
0 Flow Clog Threshold 1 Flow Sensor Clogged Threshold No.1[ADC] 0 - 1023 60