-53-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
1 Flow Clog Threshold 2 Flow Sensor Clogged Threshold No.2[ADC] 0 - 1023 68
2 Flow Clog Threshold 3 Flow Sensor Clogged Threshold No.3[ADC] 0 - 1023 83
3 Flow Clog Threshold 4 Flow Sensor Clogged Threshold No.4[ADC] 0 - 1023 102
4 Flow Clog Threshold 5 Flow Sensor Clogged Threshold No.5[ADC] 0 - 1023 120
5 Flow Clog Threshold 6 Flow Sensor Clogged Threshold No.6[ADC] 0 - 1023 134
6 Flow Clog Threshold 7 Flow Sensor Clogged Threshold No.7[ADC] 0 - 1023 145
7 Flow Clog Threshold 8 Flow Sensor Clogged Threshold No.8[ADC] 0 - 1023 158
10 Flow Inlet Err Threshold1 Flow Sensor Inlet Err Threshold No.1[ADC] 0 - 1023 102
11 Flow Inlet Err Threshold2 Flow Sensor Inlet Err Threshold No.2[ADC] 0 - 1023 151
12 Flow Inlet Err Threshold3 Flow Sensor Inlet Err Threshold No.3[ADC] 0 - 1023 186
13 Flow Inlet Err Threshold4 Flow Sensor Inlet Err Threshold No.4[ADC] 0 - 1023 234
14 Flow Inlet Err Threshold5 Flow Sensor Inlet Err Threshold No.5[ADC] 0 - 1023 263
15 Flow Inlet Err Threshold6 Flow Sensor Inlet Err Threshold No.6[ADC] 0 - 1023 316
16 Flow Inlet Err Threshold7 Flow Sensor Inlet Err Threshold No.7[ADC] 0 - 1023 340
17 Flow Inlet Err Threshold8 Flow Sensor Inlet Err Threshold No.8[ADC] 0 - 1023 376
245 Filter Roll
0 Take Up Bend Remove Filter Flexure Starts when the Value is set to 1. 0 - 1 0
1 Take Up Times Remaining Times of Filter Scroll (Read only) - -
2 Take Up Time Reset
Filter Scroll Times Reset
Resets Remaining Scroll Times when the Value is set to 10.
0 - 10 0
3 Scroll Counter Reset Time Scroll Counter Reset Times (Read only) 0 - 255 -
4 Scroll Information Cartridge No 0 - 2 0
246 Flow Clog Monitor (Read only)
0 Real Flow Data Real Flow Data [ADC] (Read only) 0 - 1023 -
1 Ideal Flow Data Theory Flow Data (Read only) 0 - 1023 -
2 Flow Difference Data Flow Difference Data [ADC] (Read only) 0 - 1023 -
3 Clog Detect Flow Difference Data Difference Data to judge the Filter Clogged [ADC] (Read only) 0 - 1023 -
4 Warn Detect Flow Difference Data
Difference Data to judge the Filter Clogged Warning [ADC] (Read
only)
0 - 1023 -
5 Press Add Data Add Data by Air Pressure (Read only) 0 - 1023 -
6 Filter Scroll Timer Timer for Filter Scroll [hour] (Read only) 0 - 32767 -
7 Air Inlet Err Difference Data Difference Data to judge the Inlet Error [ADC] (Read only) 0 - 1023 -
247 Filter Scroll Time (Read only)
0 Filter 1st Cartridge Scroll Time 1
1st Filter Cartridge Used time at N times Scrolling [hour] (N:1-10)
0 - 32767 9999
1 Filter 1st Cartridge Scroll Time 2 0 - 32767 9999
2 Filter 1st Cartridge Scroll Time 3 0 - 32767 9999
3 Filter 1st Cartridge Scroll Time 4 0 - 32767 9999
4 Filter 1st Cartridge Scroll Time 5 0 - 32767 9999
5 Filter 1st Cartridge Scroll Time 6 0 - 32767 9999
6 Filter 1st Cartridge Scroll Time 7 0 - 32767 9999
7 Filter 1st Cartridge Scroll Time 8 0 - 32767 9999
8 Filter 1st Cartridge Scroll Time 9 0 - 32767 9999
9 Filter 1st Cartridge Scroll Time 10 0 - 32767 9999
10 Filter 2nd Cartridge Scroll Time 1
2nd Filter Cartridge Used time at N times Scrolling [hour] (N:1-10)
0 - 32767 9999
11 Filter 2nd Cartridge Scroll Time 2 0 - 32767 9999
12 Filter 2nd Cartridge Scroll Time 3 0 - 32767 9999
13 Filter 2nd Cartridge Scroll Time 4 0 - 32767 9999
14 Filter 2nd Cartridge Scroll Time 5 0 - 32767 9999
15 Filter 2nd Cartridge Scroll Time 6 0 - 32767 9999
16 Filter 2nd Cartridge Scroll Time 7 0 - 32767 9999
17 Filter 2nd Cartridge Scroll Time 8 0 - 32767 9999
18 Filter 2nd Cartridge Scroll Time 9 0 - 32767 9999
19 Filter 2nd Cartridge Scroll Time 10 0 - 32767 9999
20 Filter 3rd Cartridge Scroll Time 1
3rd Filter Cartridge Used time at N times Scrolling [hour] (N:1-10)
0 - 32767 9999
21 Filter 3rd Cartridge Scroll Time 2 0 - 32767 9999
22 Filter 3rd Cartridge Scroll Time 3 0 - 32767 9999
23 Filter 3rd Cartridge Scroll Time 4 0 - 32767 9999
24 Filter 3rd Cartridge Scroll Time 5 0 - 32767 9999
25 Filter 3rd Cartridge Scroll Time 6 0 - 32767 9999
26 Filter 3rd Cartridge Scroll Time 7 0 - 32767 9999
27 Filter 3rd Cartridge Scroll Time 8 0 - 32767 9999
28 Filter 3rd Cartridge Scroll Time 9 0 - 32767 9999
29 Filter 3rd Cartridge Scroll Time 10 0 - 32767 9999
248 Filter Scroll Factor (Read only)
0 Filter 1st Cartridge Scroll Factor 1 0 - 255 255
1 Filter 1st Cartridge Scroll Factor 2 0 - 255 255

Table of Contents