Electrical Adjustment
Grp / No. Item Function Range Initial Note
32 Eco Fan Control Min Temp
Temp Sensor Control Start/End Temp at Eco
20-100 25 26 26 26
33 Eco Fan Control Max Temp 20-100 37 37 35 35
34 Eco Fan1 Min
Fan Spinning Set at Eco (Min/Max) (0.1V)
0000-9990 45 45 45 45
35 Eco Fan1 Max 0000-9990 120 120 120 120
36 Eco Fan2 Min 0000-9990 42 42 42 42
37 Eco Fan2 Max 0000-9990 120 120 120 120
38 Eco Fan3 Min 0000-9990 35 40 40 35
39 Eco Fan3 Max 0000-9990 35 40 40 35
40 Eco Fan4 Min 0000-9990 45 45 45 45
41 Eco Fan4 Max 0000-9990 120 120 120 120
42 Eco Fan5 Min 0000-9990 55 55 55 55
43 Eco Fan5 Max 0000-9990 80 80 80 80
44 Eco Fan6 Min 0000-9990 40 35 35 40
45 Eco Fan6 Max 0000-9990 40 35 35 40
46 Eco Fan7 Min 0000-9990 45 50 55 45
47 Eco Fan7 Max 0000-9990 98 98 98 98
254 (XM100) Fan Control Range Setting (Temp/Spinning) Normal Ceiling Top Bottom
16 Normal Fan Control Min Temp
Temp Sensor Control Start/End Temp at Normal
20-100 25 26 25 26
17 Normal Fan Control Max Temp 20-100 37 37 36 36
18 Normal Fan1 Min
Fan Spinning Set at Normal (Min/Max) (0.1V)
0000-9990 70 70 70 70
19
Normal Fan1 Max
0000-9990 138
138 138
138
20
Normal Fan2 Min
0000-9990 60
60 60
60
21 Normal Fan2 Max 0000-9990 138 138 138 138
22 Normal Fan3 Min 0000-9990 40 70 70 40
23 Normal Fan3 Max 0000-9990 40 70 70 40
24 Normal Fan4 Min 0000-9990 60 60 60 60
25 Normal Fan4 Max 0000-9990 138 138 138 138
26 Normal Fan5 Min 0000-9990 70 70 70 70
27 Normal Fan5 Max 0000-9990 100 100 100 100
28 Normal Fan6 Min 0000-9990 70 40 40 70
29 Normal Fan6 Max 0000-9990 70 40 40 70
30 Normal Fan7 Min 0000-9990 56 56 65 56
31 Normal Fan7 Max 0000-9990 98 98 98 98
32 Eco Fan Control Min Temp
Temp Sensor Control Start/End Temp at Eco
20-100 25 25 25 25
33 Eco Fan Control Max Temp 20-100 36 36 36 36
34 Eco Fan1 Min
Fan Spinning Set at Eco (Min/Max) (0.1V)
0000-9990 45 45 45 45
35 Eco Fan1 Max 0000-9990 120 120 120 120
36 Eco Fan2 Min 0000-9990 42 42 42 42
37 Eco Fan2 Max 0000-9990 120 120 120 120
38 Eco Fan3 Min 0000-9990 40 50 50 40
39 Eco Fan3 Max 0000-9990 40 50 50 40
40 Eco Fan4 Min 0000-9990 45 45 45 45
41 Eco Fan4 Max 0000-9990 120 120 120 120
42 Eco Fan5 Min 0000-9990 55 55 55 55
43 Eco Fan5 Max 0000-9990 80 80 80 80
44 Eco Fan6 Min 0000-9990 50 40 40 50
45 Eco Fan6 Max 0000-9990 50 40 40 50
46 Eco Fan7 Min 0000-9990 45 50 55 45
47 Eco Fan7 Max 0000-9990 98 98 98 98
255 (XM150) Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
0-255 45
1 Fan2 Initial Volt 0-255 45
2 Fan3 Initial Volt 0-255 45
3 Fan4 Initial Volt 0-255 45
4 Fan5 Initial Volt 0-255 65
5 Fan6 Initial Volt 0-255 45
6 Fan7 Initial Volt 0-255 55
8 Cooling Time Coolong Time Setting (x30 sec.) 1: 30 3: 90 15: 450 1-15 3
10 Temp Error Cooling Time
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
1-15 3
11 OnStart Cooling Start Threshold 0-100 38
12 After shutdown cooling Cooling Operation after Shut Down (0: No, 1: Yes) 0-1 1