EasyManua.ls Logo

Sanyo XM150 - Page 57

Sanyo XM150
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-57-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
255 (XM100) Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
0-255 45
1 Fan2 Initial Volt 0-255 45
2 Fan3 Initial Volt 0-255 70
3 Fan4 Initial Volt 0-255 45
4 Fan5 Initial Volt 0-255 65
5 Fan6 Initial Volt 0-255 70
6 Fan7 Initial Volt 0-255 55
8 Cooling Time Coolong Time Setting (x30 sec.) 1: 30 3: 90 15: 450 1-15 3
10 Temp Error Cooling Time
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
1-15 3
11 OnStart Cooling Start Threshold 0-100 38
12 After shutdown cooling Cooling Operation after Shut Down (0: No, 1: Yes) 0-1 1
256 Fan Lamp Voltage Down Setting
0 Lamp Voltage Current Lamp Voltage (0.1V) (Read only) 0-255 ---
1 Lamp Vol Threshold Threshold Voltage (0.1V) 30-90 30
2 Fan1 Speed Gain Fan Speed Ad Gain (0.1V) 0-1500 0
3 Fan2 Speed Gain 0-1500 10
4 Fan3 Speed Gain 0-1500 10
5 Fan4 Speed Gain 0-1500 10
10
257 Fan Setting at Dimmer
0 Dimmer Average Check Period
Dimmer Average Check Period (sec.)
0: 10, 1: 30, 2: 60, 3: 90……10:300
0-10 1
259 Fan Air Pressure Setting
0 Press Source Range Low Pressure Sensor Control Range (AD) 0-1023 661
1 Press Source Range High 0-1023 398
6 Press Fan Add Range High Add value of Fan control for Lamp Fan at Normal 0-5000 10
7 Press Fan Add Range Low 0-5000 30
8 Press Fan Add Range High Add value of Fan control for other fans at Normal 0-5000 20
9 Press Fan Add Range Low 0-5000 40
10 Press Fan Add Range High Add value of Fan control for Lamp Fan at Eco 0-5000 5
11 Press Fan Add Range Low 0-5000 15
12 Press Fan Add Range High Add value of Fan control for other fans at Eco 0-5000 20
13 Press Fan Add Range Low 0-5000 40
17 Temp A Warning Normal Highland Temp A (Room) to judge the Temp Error at Normal/Highland 0 - 100 48
18 Temp B Warning Normal Highland Temp B (Lamp) to judge the Temp Error at Normal/Highland 0 - 100 73
19 Temp CB Warning Normal Hiland Temp C (Panel) to judge the Temp Error at Normal/Highland 0 - 100 67
20 Temp A Warning Eco Highland Temp A (Room) to judge the Temp Error at Eco/Highland 0 - 100 48
21 Temp B Warning Eco Highland Temp B (Lamp) to judge the Temp Error at Eco/Highland 0 - 100 71
22 Temp C Warning Eco Hilghand Temp C (Panel) to judge the Temp Error at Eco/Highland 0 - 100 65
260 Auto Calibration (Common) * Auto calibration
0 Execute Calibration
Execute Calibration when the Value is changed. (For PC White
100%)
0 - 1 0
1 Loop Count Max Times of Calibration 1 - 30 8
2 Auto Status
Calibration Log (Read only)
0: Calibration End Correctly 1: On Adjusting 9: Calibration
Error
0 / 1 / 9 0
3 AutoWait Waiting time 1 - 20 3
4 CHECK - Tolerance Tolerance of Offset 1 - 255 4
5 Time out wait Wait Time until Time out [sec.] 1 - 255 20
261 Auto Calibration (RGB) PW392-AFE MDL <10bits>
0 OFFSET AREA H START Black Level Acq. Area H Start 0 - 1000 975
1 OFFSET AREA V START Black Level Acq. Area V Start 0 - 1000 500
2 GAIN AREA H START White Level Acq. Area H Start 0 - 1000 25
3 GAIN AREA V START White Level Acq. Area V Start 0 - 1000 500
4 Image AREA H WIDTH Black/White Level Area Width 0 - 4095 13
5 Image AREA V HEIGHT Black/White Level Area Height 0 - 4095 9
6 OFFSET Target Black Level Adj target 0 - 1023 20
7 OFFSET Tolerance Black Level Adj telerance 1 - 1023 1
8 GAIN Target White Level Adj target 0 - 1023 955
9 GAIN Tolerance White Level Adj telerance 1 - 1023 1
10 Image Level Tolerance Acq. Image Level Adj Tolerance 1 - 255 8