24  EVO1S1 | SPO1S1 Operating Instructions
 Operation
 y The scale calculates the amount to be added for each of the components that 
were already poured. The display shows the amounts required to correct the 
formula up to the point at which the overpour occurred. 
 t After the correction has been completed, you can continue filling the remaining 
components.
You can correct overpours as often as needed.
Keep in mind that the total quantity of paint (liter) at the conclusion of filling 
increases each time you correct a component. Press the § key to display the 
correction factor of the fill quantity. “C” = correction factor 
Recalculation Example (Gross Weight)
For legal metrology models, the displayed value is marked with an l symbol to 
indicate computed values.
 t Place the empty container on the weighing pan.
 y The scale shows the weight of the empty paint can.
 t Briefly press the 0 key to tare.
 t Slowly add the first component (50 g) of the formula until the display shows 
“50 g.”
 t Briefly press the ! key to save the value.
 y “STO 01” appears on the display, the first value is saved.
 y ”02” appears in the top left of the display (second color component).
 t Add the second color component “110 g” until the display shows “110 g.”
 t Briefly press the ! key to save the value.
 y “STO 02” appears on the display, the second value is saved.
 y “03” appears in the top left of the display (third color component).
 t Add the third color component (200 g) until the display shows “200 g.”
Oops! You poured in too much (203 g). The correct value for the formula is 
200.0 g. 
 t Press the P key. 
 y The recalculation is started. “C” flashes in the top left of the display.
 t Press the P key until the correct weight value “200 g” is displayed.
 t Briefly press the ! key to confirm the corrected value.
 y ”C0R 01” flashes briefly on the display (correction of the first color component).
 y ”C1” appears in the top left and the weight value to be corrected “- 1.7 g.”  
 t Add 1.7 g of the first color component until the display shows “0.0 g” or the bar 
graph stops below the green arrow.
 t Confirm the correction for the first color component by pressing the ! key.
 y ”C0R 02” flashes briefly on the display (correction of the second color 
component).
 y ”C2” appears in the top left and the weight value to be corrected “- 2.0 g.”
 t Add 2.0 g of the second color component until the display shows “0.0 g” or the 
bar graph stops below the green arrow.