Loading...
Signum 1-2-3
Settings
21
appl
appl 1
1
)
L / perc.wg Weighing in Percent
3.5. Minimum load for automatic taring and automatic printing
2
)
Numeric menu similar to Counting
3.6. Minimum load for initialization
Numeric menu similar to Counting
3.7. Automatic taring: first weight tared
2
)
Numeric menu similar to Counting
3.8.
Automatic start of applications when you switch on the device with most recently saved application data
2
)
Numeric menu similar to Counting
3.9. Reference value calculation resolution
3.9.1 * Display accuracy
3.9.2 Display accuracy + 1 decimal place
3.9.3 Display accuracy + 2 decimal places
3.9.4 Internal resolution
3.10. Decimal places in displayed result
3.10.1 * none
3.10.2 1 decimal place
3.10.3 2 decimal places
3.10.4 3 decimal places
3.11. Parameter for saving weight values
3.11.1 * With stability
3.11.2 With increased stability
3.13. Reference weighing instrument
3.13.1 * Off
3.13.2 To weighing platform WP 1
3.13.3 To weighing platform WP 2
3.15. Display of calculated values
3.15.1 * Residue
3.15.2 Loss
3.25. Tare function
2
)
Numeric menu similar to Counting
9.1. Factory settings for all application programs
2
)
9.1.1 Yes
9.1.2 No
appl 2
1
)
O / check.wg Checkweighing
3.5. Minimum load for automatic taring and automatic printing
2
)
Numeric menu similar to Counting
3.7. Automatic taring: first weight tared
2
)
Numeric menu similar to Counting
3.8.
Automatic start of applications when you switch on the device with most recently saved application data
2
)
Numeric menu similar to Counting
3.25. Tare function
2
)
Numeric menu similar to Counting
4. 2. Checkweighing range
4.2.1 * 30 to 170%
4.2.2 10% to infinity
4. 3. Control output for SET as:
4.3.1 * SET output
4.3.2 Ready to operate (for process control systems)
4. 4. Activation of outputs
4.4.1 Off
4.4.2 Always on
4.4.3 At stability
4.4.4 * Within checkweighing range
4.4.5 On at stability within checkweighing range
4. 5. Parameter input
4.5.1 * Min, Max, target value
4.5.2 Only target value with percent limits
4. 6. Automatic printing
4.6.1 * Off
4.6.2 On
4.6.3 Only values within tolerance
4.6.4 Only values outside tolerance
4. 7. Checkweighing toward zero
4.7.1 * Off
4.7.2 On
9.1. Factory settings for all application programs
2
)
9.1.1 Yes
9.1.2 No
1
) Setup level for Signum
®
3 only
2
) For Signum
®
2 only

Table of Contents