EasyManua.ls Logo

Sartorius SIWADCP - Averaging (Animal Weighing) Application V

Sartorius SIWADCP
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Signum 1-2-3
Averaging (Animal Weighing) Application V
59
Averaging (Animal
Weighing) Application V
With the Averaging application, you
can use your weighing platform for
calculating weights as the average
of a number of individual weighing
operations. These individual operations
are also known as “subweighing
operations.”
This function is used to determine
weights under unstable ambient
conditions or for weighing unstable
samples (such as live animals).
Characteristics
Averaging started manually or auto-
matically. Configured in Setup under:
appl1: anim.wg: 3.18.
With manual start selected, the
averaging routine begins when
you press a key (provided the start
conditions are met). With automatic
start selected, averaging begins when
you place the first load on the platform
(provided the start conditions are met).
Signum
®
3 only:
Enter the number of subweighing
operations using the keypad
Signum
®
2 only:
Use the r key to select the number
of measurements for averaging
Info mode
Toggle the display from “result of last
measurement” to “current weight” by
pressing the
w key
Automatic printout configured in Setup
under:
Appl: V: 3.20.
Signum
®
3:
Appl1:
anim.wg: 3.20.
Automatic taring of container weight.
Configured in Setup under:
Appl: V: 3.7.
Signum
®
3:
appl1:
anim.wg
: 3.7.
Automatic start of averaging when
the scale is turned on and a sample
placed on the platform (provided start
conditions are met). Configured in
Setup under:
Appl: V: 3.8.
Signum
®
3:
Appl: a.start: 3.8.
Exit application, delete parameters:
The number of measurements remain
in memory until the application is
changed or the value is overwritten or
deleted via the c key.
The number of measurements also
remains saved after the scale is turned
off.
Signum
®
3 only:
You can assign different functions to
the c key for deleting applications.
When you clear applications, you can
delete either the data stored for all
applications or just the data stored for
the active application. Configured in
Setup under:
Appl: sel.cf: 3.24.
(Sel. CF function key c in
applications)
Tare function:
If you store a tare (weight value) by
pressing the ) key, you can later
enter a value manually. The value you
enter is added to the stored tare value.
Setting: menu code 3.25.1 (factory
setting)
A value entered manually overwrites a
stored tare value (weight value). If you
enter a value manually, a tare value
(weight value) stored later overwrites
the manually entered value. Setting:
menu code 3.25.2
Configured in Setup under: Signum
®
2
Appl: V: 3.25.
Signum
®
3:
Appl: tare. f: 3.25.
Restore factory default settings.
Configured in Setup under:
Appl: V: 9.9.1.
Signum
®
3:
Appl: DEF.App: 9.1.
A number of subweighing operations
are required to form the basis for
calculation of an average weight.
You can enter the desired number
of subweighing operations using the
keypad.
The number you enter is active until
it is overwritten by another number.
It also remains in memory when you
switch to a different application
program, or turn off the scale.
There are three ways to start the
averaging routine:
Manual start with preset number of
subweighing operations:
Place the sample on the platform and
press the O key
Manual start with user-defined number
of subweighing operations:
Place the sample on the platform
and enter the number of weighing
operations using the keypad. Press the
r key to save the number entered
and begin weighing.
Automatic start with preset number of
subweighing operations:
Measurement begins when you place
the first sample on the platform,
provided the start conditions are met.
Neutral Measurement Application Z
nM

Table of Contents

Other manuals for Sartorius SIWADCP