42
Step
(Shown
below, near
the gear icon)
Display
on
display
Selectable values
(in brackets is the factory
default value)
Description
3
AL
From 5 to 20 (5)
Minimum option of setting the heating temperature in
degrees °C. With this option, you can limit the heating
temperature that can be set using the thermostat.
4
FH
From 20 to 70 (40)
Maximum set temperature of floor heating in °C. You can
limit the maximum set floor heating temperature.
5
FL
From 5 to 20 (5)
Lowest set temperature of floor heating in °C. You can
limit the minimum set floor heating temperature.
6
SEN
AL / In / OU (In)
Thermostat mode Use of internal or external sensors.
AL The thermostat uses both sensors for temperature
readinternal and external underfloor.
In Thermostat uses internal temperature sensor only.
OU Thermostat uses external underfloor temperature
sensor only.
7
bL
2 / 3 (2)
Use this option to change the screen brightness.
2 Screen backlight lasts 30 seconds;
3 Screen backlight is always turned on
8
P51
0 / 7 (0)
Heating Schedule programs.
Here you can turn on/off and set on how the heating
program schedule will work.
0 The heating program schedule is turned off;
7 7 days (each day separately; table 1)