中文
EN DE RU KO PT JA ES
03015/03017
31
Frequency range: 40Hz~400Hz
Display: sine wave rms (average response)
Maximum measured current: 20A (for measured current higher than 2A: duration < 10s, measurement interval > 15min)
Note: The accuracy of the 20A range is valid from 20% to 100% of the range.
Input voltage: 4-10Vp-p
Frequency: 4Hz-1kHz
AC current:
Duty cycle:
Range
Resolution Accuracy
03015 03017
400.0μA 600.0μA 0.1μA
±(1.8%+10)
4000μA 6000μA 1.0μA
40.00mA 60.00mA 0.01mA
400.0mA 600.0mA 0.1mA
4.000A 6.000A 1A
±(2.5%+10)
20A 20A 10A
Range Resolution Accuracy
5%-95% 0.1% ±(2.0%+3)
Resistance:
Range
Resolution Accuracy
03015 03017
400.0Ω 600.0Ω 0.1Ω ±(1.0%+5)