SATEL TD-1 7
S Gıı - when the temperature change was faster than that allowed for the external sensor.
SoFF - disabled.
F13 – relay output 1 type
1 NO - normally open.
1 NC - normally closed.
F14 – relay output 2 type
2 NO - normally open.
2 NC - normally closed.
7. Restoring factory settings
In order to restore the factory settings, turn off the power and then turn it on again while
holding down the and keys.
8. Specifications
Supply voltage ................................................................................................... 12 V DC ±15%
Standby current consumption ................................................................................15 mA ±20%
Maximum current consumption........................................................................................50 mA
Relay contacts rating (resistive load) ................................................................... 1 A / 30 V DC
Environmental class................................................................................................................. II
Working temperature range ...............................................................................- 10°C...+ 55°C
Enclosure dimensions......................................................................................48 x 78 x 18 mm
Weight............................................................................................................................... 108 g
The declaration of conformity may be consulted at www.satel.eu/ce
SATEL sp. z o.o.
ul. Budowlanych 66
80-298 Gdańsk
POLAND
tel. + 48 58 320 94 00
www.satel.eu