−60
7-5. Setting the Preset Start
Setting the Date and Time
This function is used to specify the date and time to start logging
automatically.
Notes: Starting this operation clears the logged data stored on the
Datalogger depending on the logging option that has been set.
Always download the necessary data before setting this function.
For further information, please see the table below.
Logging Option Data stored on the Datalogger
Once (default) Erased
Repeatedly (overwriting) Erased
Ends at…
(limited amount)
Erased
By pages (partitioning) Not erased.
The setting is retained in the free memory
block (page). To perform a preset start, there
must be at least one free block to store data.
If no free block is left, erase the data in a
block rst.
For instructions on how to erase data, please
see step (9) of Chapter 5 "Basic Operation".