WS4-DT-r01-30-12-16TM
3.1
Media Sensor Calibration
Each type of media roll has its own label separators, such as gaps, holes, notches
or black marks. Those separators need to be detected by media sensors, so the
label can be printed in correct position. SATO WS4 DT printers provide
transmissive and reflective sensor calibration for media detection. Do the
following to use them.
1. Make sure the media is properly loaded, the print module is closed and your
printer’s power switch is set to the OFF position.
2. Press and hold the FEED button and turn on your printer.
3. Both status lights glow solid orange for a few seconds. Next, they turn to green
shortly, and then turn to other colors. Do one of the following to select the
sensor:
●
If you want to calibrate the transmissive sensor, when LED 1 turns to green and
LED 2 turns to red, release the FEED button immediately.
●
If you want to calibrate the reflective sensor, when LED 1 turns to green and
LED 2 turns to orange, release the FEED button immediately.
4. Press the FEED button. The media calibration is complete after your printer
feeds 3-4 labels and stops.