12
3) The display shows “UnLoAd”: unload the scale and press TARE.
4) The displays show “LoAd X KiLoS”, in which X is the sample weight to be put on the scale; press several time the
SAVE key if one wants to change the calibration weight.
5) Put the weight on the scale, please wait for the weight stability and press TARE.
6) If the calibration is correct, the displays show for an instant “SPAN PASS”, and then “CAL F0”.
If the calibration is uncorrect, the displays show for an instant “SPAN FAIL LOW” (if the weight is too low) or “SPAN
FAIL HI” (if the weight is too high) and then “CAL F0”.
IN CASE THE ZONE OF USE IS DIFFERENT FROM THE CALIBRATION ZONE ONE SHOULD:
1) Carry out the calibration as previously described.
2) Enter the F16 step and set the gravity acceleration value for the ZONE OF USER.
3) Press the TARE key to confirm
4) Save and exit the SET-UP environment (press many times the ZERO key).
5) The weight error, caused by the different gravitational attraction value between the calibration zone and the zone of use,
is corrected automatically.
“F1” - NUMBER OF DIVISIONS (*)
By pressing TARE one selects the scale divisions number.
Press SAVE key to select one value of the following:
Value Divisions
1 3000 3000
1 6000 6000
dUAL rAnGE 3000 + 3000
“F2” - MAIN PRICE UNIT
By pressing TARE one selects the main price unit.
Press SAVE to select one of the possible unit:
kiLoS kilogram
100 100 grams
“F3” - SCALE CAPACITY (*)
By pressing TARE one selects the total capacity of the scale.
Press SAVE key to select one of these capacities: 3, 6, 15, 30 kg.
“F4” - NUMBER OF SCALE DECIMALS (*)
By pressing TARE one selects the number of scale decimals.
Press SAVE to select one of the suggested values: 0.0 (a decimal), 0.00 (two decimals), 0.000 (three decimals), 0.0000
(four decimals), 0 (no decimal); confirm with ZERO.
“F5” - NUMBER OF AMOUNT DECIMALS
By pressing TARE one selects the number of amount decimals.
Press SAVE to select one of the suggested values: 0.0 (a decimal), 0.00 (two decimals), 0 (no decimal).
“F6” - AUTOMATIC ZERO AT START-UP (*)
Trough this step one sets the weight percentage for the automatic acquisition of the gross zero at start-up. If at the start-up
a weight is detected that is within the programmes percentage of the total capacity, it will be cleared; if the weight is not
within this tolerance, the display, after a few instants, shows the current weight.
Press SAVE to select one of the suggested percentages: from 0 to 20.