13
“F7” - MANUAL ZERO RANGE (*)
Trough this step one sets the weight percentage for the manually acquiring the gross zero; if, in the normal weighing phase,
by pressing ZERO, a weight within the programmed percentage of the total capacity, it will be cleared.
Press SAVE to select one of the suggested percentages: from 0 to 20.
“F8” - LIMITATION OF THE TARE FUNCTIONS (*)
on limitation
disabled
oFF limitation
enabled
Refers to the 6.3.1 section for the functioning mode.
“F9” - A/D CONVERTER POINTS
By pressing TARE the instrument shows the A/D converter points relative to the weight on the scale.
By pressing ZERO one zero the value.
Press TARE to exit the step.
“F10” - SPEED SETTING ADC CONVERTER READING SPEED
By pressing TARE one sets the reading speed of the ADC converter; the set value corresponds to the number of readings
made in a second.
Press SAVE to select one of the suggested reading speeds: 7.5, 15, 30, 60.
“F11” - BAUD RATE
By pressing TARE one selects the baud rate.
Press SAVE to select one of the possible speeds: 2400, 4800, 9600, 19200.
“F12” - MINIMUM AMOUNT DIVISION
By pressing TARE one selects the minimum amount division.
Press SAVE to select one of the suggested values: 1, 2, 5, 10.
“F13” - SERIAL TRANSMISSION (*)
off disabled
PRNTR totalisation and transmission to printer enabled
ECR not used in this application.
“F14” - PRICE INTRODUCTION MODE
FLoAt introduction with floating decimal point
FiXEd introduction with fixed decimal point
“F15” - PRINTING LANGUAGE AND CURRENCY SYMBOL
By pressing TARE one selects the printing language.
Press SAVE to select one of the suggested values: En, it, ES, Fr, DE.
By confirming with TARE one sets the symbol of the currency to be printed.
Enter the ASCII decimal code of the CURRENCY and press TARE.
“F16” - GRAVITY ZONE OF USE (*)
Through this step one selects the acceleration value of use of the instrument:
Manual entry of the g value: one may manually enter the gravitational acceleration value; one must modify the 6 decimal
digits of the gravitational acceleration.
In case one enters a wrong g value:
the minimum decimal value is suggested (9,75001); a wrong value is any decimal
number that is not between 9,75001 and 9,84999 (inclusive).
“F17” - RESET (*)
For use of the manufacturer.