Schiller Grounds Care, Inc. P/N 802-0006
APPENDIX B RELATED DOCUMENTATION
CORRECTIVE ACTION
FOR OVERFILLED OIL
If you suspect the engine oil is overlled, the following procedure should remove the excess oil. The excess oil must be pumped
out as the engine runs and cannot be removed by simply pouring out of the oil ll opening. Checking the oil level and draining any
excess between multiple 30-second running intervals will bring the oil back to the proper level.
1. Place the engine on a level surface resting at on the front carry handle and remove the oil ll cap/dipstick. Use a catch basin for
any oil that overows from the oil ll opening.
DIPSTICK
2. Replace the oil ll cap / dipstick, position the machine in an upright position, and run the engine for approximately 30 seconds
then repeat step one. Continue steps 1 & 2 until oil no longer overows when the oil ll cap/ dipstick is removed.
3. Once the oil level is corrected, the engine may continue to smoke while running for several minutes while the residual oil burns
off.