Operating panel
Integral MAP
User manual
FIRE ALARMEN

Other manuals for Schrack Seconet Integral MAP

Question and Answer IconNeed help?

Do you have a question about the Schrack Seconet Integral MAP and is the answer not in the manual?

Summary

General Information

Explanation of Symbols

Explains symbols used in the document for notes, cautions, and environmental notices.

General Safety Notes

System Overview

Acoustic Signals

Describes the five different acoustic modes used by the Integral MAP for alarms and signals.

Buttons and LEDs During Alarm

Explains the function of buttons and LEDs during an alarm event, including fire alarms and delay layers.

Operation Region Display and Controls

Details the display elements and operational buttons within the main control panel interface.

Status and Fault Indication

Explains the meaning of various LEDs indicating system status, faults, power, and disablements.

Transmission Equipment Controls

Describes the buttons and LEDs associated with transmission equipment for alarm reporting to external services.

Alarm System (Sirens) Controls

Explains the function of buttons and LEDs controlling acoustic and visual alarm devices (sirens).

System Operation During Alarm

Fire Alarm Procedure

Details visual and acoustic indications during a fire alarm and initial response steps.

Delay Layer Functionality

Explains the activation and deactivation of the delay layer function for managing alarm responses.

Exploration and Intervention Function

Describes how to activate the intervention mode for investigating and managing alarms with delayed outputs.

Resetting Alarm and Fault Signals

Explains how to silence or reset active alarm and fault signal tones.

Silencing or Disabling Sirens

Details procedures for muting or disabling sirens and alarm areas, including authorization levels.

Alarm Reset Process

Outlines the process and conditions for resetting an alarm, requiring authorization and problem resolution.

Transmission System Activation

Informs about the transmission system status when location assistance has been contacted and advises on next steps.

General Operating Procedures

Alarms, Faults, and Lists

Explains how to view and navigate lists of alarms, faults, and other system events.

Fault Message Interpretation

Details how to interpret and respond to various fault messages, including device and module faults.

Querying Element States

Guides on selecting specific elements and querying their current operational states.

Authorization Levels for Operation

Describes how to change authorization levels to access different system functions and operations.

Operating System Elements

Explains how to perform operations on selected elements, including turning them on/off or resetting functions.

Range Operation for Elements

Details how to operate multiple elements of the same type simultaneously using range selection.

Alarm Counter Query

Explains how to access the menu to view the count of accumulated alarms.

System Settings

Menu Functions

Explains how to navigate the system menu to access various configuration options.

Delay Changeover Periods

Details how to view programmed times for automatic switching between operating modes.

Log Printer Management

Activate or Disable Log Printer

Details the procedure for activating or deactivating the log printer function with authorization.

Repeating Log Prints

Guides on how to repeat prints of various log lists like event logs, faults, and disablements.

Schrack Seconet Integral MAP Specifications

General IconGeneral
Storage Temperature-20°C to +60°C
NetworkingEthernet, RS-485
RedundancyOptional redundant power supply
Power Supply24 V DC
Standards ComplianceEN 54-2, EN 54-4
Relative HumidityUp to 95%, non-condensing
Protection ClassIP30
Communication InterfaceEthernet, RS-485
ProtocolModbus, proprietary protocol
TypeModular Fire Alarm Control Panel