Maintenance
26
02.00 | KHM | Assembly and Operating Manual | en | 389171
6 Maintenance
6.1 Notes
Original spare parts
Use only original spare parts of SCHUNK when replacing spare and
wear parts.
Maintenance
It is recommended that you have maintenance work and change of
seals carried out at SCHUNK. However, you can also do the
maintenance work and change the seals yourself.
6.2 Maintenance and care intervals
NOTICE
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
• Reduce the lubricant intervals accordingly.
Size KHM 40
Interval [Mio. cycles] 2
6.3 Lubricants/Lubrication points (basic lubrication)
SCHUNK recommends the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly
apply lubricant with a lint-free cloth.
Lubricant point Lubricant
Sliding metal Molykote BR 2 plus
Metallic sliding surfaces Renolit HLT 2
All seals Renolit HLT 2
Sliding surfaces outside the
cylinder
Metaflux