C2648 Prodigy and Prodigy Plus Service Manual
January 2015
Page 10
For The Installer: Remote Condenser
Locate the condenser as near as possible to the
interior location of the ice machine.
Note: The location of the condenser is relative to
the ice machine is LIMITED by the specication on
the prior page.
Meet all applicable building codes.
Roof Attachment
Install and attach the remote condenser to the roof
of the building, using the methods and practices of
construction that conform to the local building codes,
including having a roong contractor secure the
condenser to the roof.
Interconnecting Tubing
Remote
Condenser
Ice Machine
Power Supply
Remote Condenser, Typical System Illustration