EasyManua.ls Logo

Scotsman C2648 - Electrical Component Details; Compressor Operation; Contactor Operation; Water Pump Operation

Scotsman C2648
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C2648 Prodigy and Prodigy Plus Service Manual
January 2015
Page 30
Electrical Component Details
Compressor
Operated by the compressor contactor.
Contactor
Operated by the controller and the high pressure cut out switch. Line voltage coil. When energized the
Compressor indicator light will be ON.
Water Pumps
Operated by the controller, one of them thru a NC relay. When the Pump light is ON during a Freeze cycle,
both pumps should be operating. When the Pump and Purge lights are both ON, one pump will be ON and
one will be OFF.
Inlet Water Solenoid Valve
Operated by the controller. Line voltage coil. When energized, the Water Solenoid indicator light will be ON.
Purge Valve
Operated by the controller. Line voltage coil. When energized, the Purge Valve indicator light will be ON.
Energized for a time during harvest.
Fan Motor
Remote condenser fan motor is on whenever the compressor is.
High pressure cut out
There is a high pressure cut out switch that shuts the power off to the compressor contactor if the
discharge pressure is too high. It is an automatic reset.
Harvest Assists - Originally solenoids later units have motors
Operated by the controller through a relay. In parallel with the hot gas valve. Cycles on and off at the
beginning of a restart. Energized throughout the harvest cycle. Line voltage coil.
Liquid Line Valve
Opened by the controller to start a freeze cycle. Closed to shut unit off. Line voltage coil.
Hot Gas Valves
Operated by the controller through a relay. In parallel with the harvest assist. Cycles on and off at the
beginning of a restart. Energized throughout the harvest cycle. Line voltage coil.

Other manuals for Scotsman C2648