C2648 Prodigy and Prodigy Plus Service Manual
January 2015
Page 38
Restarts
Power Interruption
The controller will automatically restart the ice machine after adequate voltage has been restored.
• H blinks on code display
• Status indicator light blinks
• Reservoir is drained and relled
Default harvest is initiated. The curtain switch does not have to open to terminate harvest, harvest will continue
until the default harvest time expires. Default harvest time is 3 minutes. The machine will then return to a
normal freeze cycle.
Water Interruption
• The controller will attempt to ll the reservoir every twenty minutes until it is successful.
On-Off Switch Access
All models ship with the On and Off switches front accessible. If desired, the On and Off switches can be
covered by changing the bezel in the front panel’s trim strip. The Prodigy Plus models have the switches in the
lower left corner, and they can also be covered up by a xed door. See illustration below.