6 Commands
59
6.31 CWWeight
Default setting: 50
Parameter: X 5... 95, weight of CW characters in %.
This command sets the weighting of the CW character, that is dot dash relationship,
together with dot space ratio (between character elements). Standard CW shows a ratio
between dots and spaces of 1. The dot dash relationship is 3 to 1. With lighter CW
characters, the ratio between dot and dash length is larger than 3, and the space to dot
relationship greater than 1.
With a CWWeight value of 50 (%), the PTC operates with normal ratios. With values
greater than 50, the weight of the characters increase, and with smaller values, they
decrease (percentage-wise). A weight of 25 means that the dot length would be only half
that of the normal setting, the space length being respectively longer, this leading to a
space to dot ratio of 3 to 1. The speed naturally stays the same, as the complete character
length is not influenced by CWWeight.
The value of CWWeight influences the CW identification as well as the CW terminal.
6.32 CYcle
Default setting: 2
Parameter: 0 Always switching to short cycles.
1 Always switching to long cycles.
2 Adapt cycle length adaptive.
CYcle defines the cycle length used for a PACTOR-2 connect. Usually it is just used for
test purposes (speed comparison, etc). and is described here for the sake of completeness.
6.33 DAte
Remote
Default setting: none
Parameter: DD.MM.YY Desired date.
Arguments are ignored during remote control.
DAte is used to set or read the PTC calendar. If DAte is entered without a parameter, the
PTC-IIIusb displays the current date.
All positions have to be entered. Leading zeros must not be omitted. The periods for
separation are not necessary. Faulty inputs cause incorrect settings!
From 01.01.1990 up to 31.12.2089, the day of the week is automatically calculated from
the date. Thus your PTC-IIIusb is well equipped for the future.
Required date Sunday 24th March 2005.
cmd: DA 24.03.05 <Return>
Or in shortform
cmd: DA 240305 <Return>