26 User Manual 62C/62S
5.1.4 Error indications
When an error is detected, one or more LED’s are flashing and any rotation will stop.
Power indicator flashing;
Machine is in stand-by mode. The power is on and the optical safety device is active.
Press the control ON/OFF button to activate the machine.
Forward indication flashing;
Motor overload.
Press the stop button and check the material flow and the tension setting of the unwind
shafts.
Reverse indicator flashing;
Motor overload.
Press the stop button and check the material flow and the tension setting of the wind-up
shafts.
Forward and reverse indicator flashing;
System error.
Disconnect and then reconnect the power. If the error persists, contact your service
organization.
All four pressure indication LED’s are flashing;
Pressure too high or nip setting too narrow.
The LED’s start flashing at 10% overload. When the pressure exceeds a 20% overload an
audible signal is generated. Increase the nip to lower the pressure.