Troubleshooting Possible causes Solutions Reference pages
Misalignment of
date
After the reception is successful, the
time is correct but the date is incorrect.
The preliminary position of the date is out of alignment.
This problem occurs when the preliminary position of the date is out of
alignment due to external influence etc.
Adjust the preliminary position of the date to the correct position “1” (the first day of a month). P. 52 - 55
Misalignment of
day of the week
After the reception is successful, the
time is correct but the date is incorrect.
The preliminary position of the multi-function indicator hand is incorrect.
This occurs when the preliminary position of the multi-function indicator hand
is misaligned due to external factors.
Adjust the preliminary position of the multi-function indicator hand to the correct
position of “low” (charging status display).
P. 52 - 55
The sub-dial
cannot be
adjusted.
After the reception is successful, the
basic time is correct but the time zone
selected on the sub-dial is not
displayed.
The preliminary position of the sub-dial is out of alignment.
This problem occurs when the preliminary position of the sub-dial is out of
alignment due to external influence etc.
Correctly adjust the sub-dial and the AM/PM hand to the preliminary position of
“12:00 AM”.
P. 52 - 55
Misalignment of
multi-function
indicator hand
The position of the hand showing the
reception way, charging status, in-
flight mode (
), and DST is
misaligned
The automatic leap second reception function has been
activated, and the indicator hand indicates the “LS”
It takes up to 18 minutes to complete the leap second reception.
Use the watch with reference to the P. 18.
P. 33
The preliminary position of the multi-function indicator hand is incorrect.
This occurs when the preliminary position of the multi-function indicator hand
is misaligned due to external factors.
Adjust the preliminary position of the multi-function indicator hand to the correct
position of “low” (charging status display).
P. 52 - 55
Misalignment of
stopwatch hands
The stopwatch hands do not correctly
display the 0-second position after
resetting.
The preliminary positions of the stopwatch hands are incorrect. Correctly set the preliminary positions of the stopwatch hands. P. 52 - 55
Stopwatch
measurement
Rapid advancement of the main-dial
(hour, minute, seconds) temporarily
stops during stopwatch
measurement.
The stopwatch 1/20-second hand is running (maximum of one minute).
Wait without doing anything.
When the stopwatch 1/20-second hand stops at the 0-second position, the main-dial will resume rapid
advancement.
-
59