-28-
5. How to use a reflected luminance (cd/m
2
or FL) meter
1. Make sure that any compensation (see page 29) is canceled.
2. Set the meter to Cd/m
2
or Foot-lambert mode for reflected light with custom setting (see page
33).
3. Set meter to spot reading for reflected light.
Take the measurement by looking through the finder and aligning so the subject that will be
measured is inside the circle.
6. Advanced Functions
* EV value → Foot-lambert (FL)
conversion table
3
4
5
6
7
8
9
10
11
0.09
0.19
0.37
0.74
1.5
3.0
5.9
12
24
0.13
0.26
0.53
1.1
2.1
4.2
8.4
17
34
12
13
14
15
16
17
18
19
48
95
190
380
760
1500
3000
6100
67
140
270
540
1100
2200
4300
8600
EV
0
0.5
0 0.5
Decimal places
EV
Decimal places
* EV value → cd/m
2
conversion table
3
4
5
6
7
8
9
10
11
1
2
4
8
16
32
64
130
260
1.4
2.8
6
11
23
45
91
180
360
12
13
14
15
16
17
18
19
510
1000
2000
4100
8200
16000
33000
66000
720
1400
2900
5800
12000
23000
46000
93000
EV
EV
Decimal places
0
0.5
0
0.5
Decimal places
Reference:
• Setting the meter to EV mode (DIP switch 1) and ISO 100, the measured EV can be
converted to find the brightness level with the below conversion table.